P0B7F – High Voltage in Hybrid/Electric Vehicle Battery Circuit 14

P0B7F Possible Causes

  • Defective hybrid/electric vehicle battery
  • Faulty hybrid/electric vehicle battery interface control module

What Does It Mean?

How to Fix P0B7F Code

Check the “possible causes” listed above. Visually inspect the wiring harness and related connectors. Check for damaged components and look for broken, bent, pushed out, or corroded connector pins.

P0B7F Possible Symptoms

Check engine light illuminated (or service engine soon warning light)

P0B7F Meaning

The hybrid/electric vehicle battery contains 288 cells. Groups of three cells are welded together in parallel. There are a total of 96 cell groups in the hybrid/EV battery pack. These cell groups are electrically connected in series. Each individual cell group is rated at 3.7 V, for a nominal system voltage of 355 V DC. The battery cells are also grouped into three sections. The first 90 cells/30 cell groups make up the first battery section. This section is adjacent to the hood and contains batteries 67 to 96. Battery section two is located behind section one. It consists of 72 cells/24 cell groups and contains batteries 43 to 66. The battery cross-section is section number three, it consists of the remaining 126 cells/42 cell groups and contains batteries 1 to 42. The three battery sections are individually repairable components.

The battery energy control module monitors the voltage of the 96 battery cell groups via the four hybrid/EV battery interface control modules. Voltage sensing circuits are attached to each individual cell group, and these sensing circuits terminate at a connector located on the top surface of the battery section. A repairable auxiliary battery wiring harness connects this connector to a hybrid/EV battery interface control module, also located on the top surface of the battery section. The hybrid/EV battery interface control module encodes the voltage reading and transmits it to the battery energy control module via the battery control harness. There is one hybrid/EV battery interface control module located on battery sections one and two, and two hybrid/EV battery interface control modules associated with battery section three. The hybrid/EV battery interface control module, battery energy control module wiring harness, auxiliary battery wiring harness, and battery energy control module are all considered repairable components.

The battery energy control module will determine when a fault condition is present. System diagnostics and status are communicated from the battery energy control module to the hybrid/EV powertrain control module 2 via serial data. The hybrid/EV powertrain control module 2 is the host controller for diagnostic trouble code information.

P0B80 – Intermittent/Erratic Hybrid Battery Voltage Detection Circuit

P0B80 Possible Causes

  • Faulty battery smart unit
  • Faulty HV battery assembly

What Does It Mean?

How to Fix P0B80 Code

Check the “Possible Causes” listed above. Visually inspect the related wiring harness and connectors. Check for damaged components and look for broken, bent, pushed out, or corroded connector pins.

P0B80 Possible Symptoms

Check engine light illuminated (or service engine soon warning light)

P0B80 Meaning

The HV battery uses nickel-metal hydride batteries and does not require external charging. The power management control ECU maintains the HV battery’s SOC (state of charge) at a constant level during driving. The HV battery consists of 28 modules, with each module containing eight 1.2V cells connected in series. The battery smart unit monitors the battery block voltage at 14 locations. Each battery block consists of 2 modules in one assembly. The battery smart unit, which monitors the battery block voltages, determines that a malfunction has occurred if the voltage difference between battery blocks exceeds the standard. When the malfunction detection condition is met, the power management control ECU (HV CPU) illuminates the malfunction indicator light (MIL) and sets a diagnostic trouble code (DTC).

P0B81 – Hybrid/Electric Vehicle Battery 15 Circuit

P0B81 Possible Causes

  • Defective hybrid/electric vehicle battery
  • Faulty hybrid/electric vehicle battery interface control module

What Does It Mean?

How to Fix P0B81 Code

Check the “possible causes” listed above. Visually inspect the related wiring harness and connectors. Check for damaged components and look for broken, bent, pushed out, or corroded connector pins.

P0B81 Possible Symptoms

Check engine light illuminated (or service engine soon warning light)

P0B81 Meaning

The hybrid/electric vehicle battery contains 288 cells. Groups of three cells are welded together in parallel. There are a total of 96 cell groups in the hybrid/EV battery pack. These cell groups are electrically connected in series. Each individual cell group is rated at 3.7 V, for a nominal system voltage of 355 V DC. The battery cells are also grouped into three sections. The first 90 cells/30 cell groups make up battery section one. This section is adjacent to the hood and contains batteries 67 to 96. Battery section two is located behind section one. It consists of 72 cells/24 cell groups and contains batteries 43 to 66. The battery cross-section is section number three, it consists of the remaining 126 cells/42 cell groups and contains batteries 1 to 42. The three battery sections are individually serviceable components.

The battery energy control module monitors the voltage of the 96 battery cell groups via the four hybrid/EV battery interface control modules. Voltage sensing circuits are attached to each individual cell group, and these sensing circuits terminate at a connector located on the top surface of the battery section. A serviceable auxiliary battery wiring harness connects this connector to a hybrid/EV battery interface control module, also located on the top surface of the battery section. The hybrid/EV battery interface control module encodes the voltage reading and transmits it to the battery energy control module via the battery control harness. There is one hybrid/EV battery interface control module located on battery sections one and two, and two hybrid/EV battery interface control modules associated with battery section three. The hybrid/EV battery interface control module, battery energy control module wiring harness, auxiliary battery wiring harness, and battery energy control module are all considered serviceable components.

The battery energy control module will determine when a fault condition is present. System diagnostics and status are communicated from the battery energy control module to the hybrid/EV powertrain control module 2 via serial data. The hybrid/EV powertrain control module 2 is the host controller for diagnostic trouble code information.

P0B82 – Performance of Battery Circuit 15 in Hybrid/Electric Vehicles

P0B82 Possible Causes

  • Defective hybrid/electric vehicle battery
  • Faulty hybrid/electric vehicle battery interface control module

What Does It Mean?

How to Fix P0B82 Code

Check the “possible causes” listed above. Visually inspect the related wiring harness and connectors. Check for damaged components and look for broken, bent, pushed out, or corroded connector pins.

P0B82 Possible Symptoms

Check engine light illuminated (or service engine soon warning light)

P0B82 Meaning

The hybrid/electric vehicle battery contains 288 cells. Groups of three cells are welded together in parallel. There are a total of 96 cell groups in the hybrid/EV battery pack. These cell groups are electrically connected in series. Each individual cell group is rated at 3.7 V, for a nominal system voltage of 355 V DC. The battery cells are also grouped into three sections. The first 90 cells/30 cell groups make up battery section one. This section is adjacent to the hood and contains batteries 67 to 96. Battery section two is located behind section one. It consists of 72 cells/24 cell groups and contains batteries 43 to 66. The battery cross-section is section number three, it consists of the remaining 126 cells/42 cell groups and contains batteries 1 to 42. The three battery sections are individually serviceable components.

The battery energy control module monitors the voltage of the 96 battery cell groups via the four hybrid/EV battery interface control modules. Voltage sensing circuits are attached to each individual cell group, and these sensing circuits terminate at a connector located on the top surface of the battery section. A serviceable auxiliary battery wiring harness connects this connector to a hybrid/EV battery interface control module, also located on the top surface of the battery section. The hybrid/EV battery interface control module encodes the voltage reading and transmits it to the battery energy control module via the battery control harness. There is one hybrid/EV battery interface control module located on battery sections one and two, and two hybrid/EV battery interface control modules associated with battery section three. The hybrid/EV battery interface control module, battery energy control module wiring harness, auxiliary battery wiring harness, and battery energy control module are all considered serviceable components.

The battery energy control module will determine when a fault condition is present. System diagnostics and status are communicated from the battery energy control module to the hybrid/EV powertrain control module 2 via serial data. The hybrid/EV powertrain control module 2 is the host controller for diagnostic trouble code information.

P0B83 – Low Voltage in Hybrid/Electric Vehicle Battery Circuit 15

P0B83 Possible Causes

  • Defective hybrid/electric vehicle battery
  • Faulty hybrid/electric vehicle battery interface control module

What Does It Mean?

How to Fix P0B83 Code

Check the “possible causes” listed above. Visually inspect the related wiring harness and connectors. Check for damaged components and look for broken, bent, pushed out, or corroded connector pins.

P0B83 Possible Symptoms

Check engine light illuminated (or service engine soon warning light)

P0B83 Meaning

The hybrid/electric vehicle battery contains 288 cells. Groups of three cells are welded together in parallel. There are a total of 96 cell groups in the hybrid/EV battery pack. These cell groups are electrically connected in series. Each individual cell group is rated at 3.7 V, for a nominal system voltage of 355 V DC. The battery cells are also grouped into three sections. The first 90 cells/30 cell groups make up the first battery section. This section is adjacent to the hood and contains batteries 67 to 96. Battery section two is located behind section one. It consists of 72 cells/24 cell groups and contains batteries 43 to 66. The battery cross-section is section number three, it consists of the remaining 126 cells/42 cell groups and contains batteries 1 to 42. The three battery sections are individually repairable components.

The battery energy control module monitors the voltage of the 96 battery cell groups via the four hybrid/EV battery interface control modules. Voltage sensing circuits are attached to each individual cell group, and these sensing circuits terminate at a connector located on the top surface of the battery section. A serviceable auxiliary battery wiring harness connects this connector to a hybrid/EV battery interface control module, also located on the top surface of the battery section. The hybrid/EV battery interface control module encodes the voltage reading and transmits it to the battery energy control module via the battery control harness. There is one hybrid/EV battery interface control module located on battery sections one and two, and two hybrid/EV battery interface control modules associated with battery section three. The hybrid/EV battery interface control module, battery energy control module wiring harness, auxiliary battery wiring harness, and battery energy control module are all considered serviceable components.

The battery energy control module will determine when a fault condition is present. System diagnostics and status are communicated from the battery energy control module to the hybrid/EV powertrain control module 2 via serial data. The hybrid/EV powertrain control module 2 is the host controller for diagnostic trouble code information.

P0B84 – High Voltage in Hybrid/Electric Vehicle Battery Circuit 15

P0B84 Possible Causes

  • Defective hybrid/electric vehicle battery
  • Faulty hybrid/electric vehicle battery interface control module

What Does It Mean?

How to Fix P0B84 Code

Check the “possible causes” listed above. Visually inspect the related wiring harness and connectors. Check for damaged components and look for broken, bent, pushed out, or corroded connector pins.

P0B84 Possible Symptoms

Check engine light illuminated (or service engine soon warning light)

P0B84 Meaning

The hybrid/electric vehicle battery contains 288 cells. Groups of three cells are welded together in parallel. There are a total of 96 cell groups in the hybrid/EV battery pack. These cell groups are electrically connected in series. Each individual cell group is rated at 3.7 V, for a nominal system voltage of 355 V DC. The battery cells are also grouped into three sections. The first 90 cells/30 cell groups make up battery section one. This section is adjacent to the hood and contains batteries 67 to 96. Battery section two is located behind section one. It consists of 72 cells/24 cell groups and contains batteries 43 to 66. The battery cross-section is section number three, it consists of the remaining 126 cells/42 cell groups and contains batteries 1 to 42. The three battery sections are individually serviceable components.

The battery energy control module monitors the voltage of the 96 battery cell groups via the four hybrid/EV battery interface control modules. Voltage sensing circuits are attached to each individual cell group, and these sensing circuits terminate at a connector located on the top surface of the battery section. A serviceable auxiliary battery wiring harness connects this connector to a hybrid/EV battery interface control module, also located on the top surface of the battery section. The hybrid/EV battery interface control module encodes the voltage reading and transmits it to the battery energy control module via the battery control harness. There is one hybrid/EV battery interface control module located on battery sections one and two, and two hybrid/EV battery interface control modules associated with battery section three. The hybrid/EV battery interface control module, battery energy control module wiring harness, auxiliary battery wiring harness, and battery energy control module are all considered serviceable components.

The battery energy control module will determine when a fault condition is present. System diagnostics and status are communicated from the battery energy control module to the hybrid/EV powertrain control module 2 via serial data. The hybrid/EV powertrain control module 2 is the host controller for diagnostic trouble code information.

P0B85 – Intermittent/Erratic Hybrid Battery Voltage Detection Circuit

P0B85 Possible Causes

  • Faulty intelligent battery unit
  • Faulty HV battery assembly

What Does It Mean?

How to Fix P0B85 Code

Check the “possible causes” listed above. Visually inspect the related cable harness and connectors. Check for damaged components and look for broken, bent, pushed out, or corroded connector pins.

P0B85 Possible Symptoms

Engine light on (or service engine soon warning light)

P0B85 Meaning

The HV battery uses nickel-metal hydride batteries and does not require external charging. The power management control ECU maintains the HV battery SOC (state of charge) at a constant level during driving. The HV battery consists of 28 modules, with each module containing eight 1.2V cells connected in series. The intelligent battery unit monitors the battery block voltage at 14 locations. Each battery block consists of 2 modules in an assembly. The intelligent battery unit, which monitors battery block voltages, determines that a malfunction has occurred if the voltage difference between battery blocks exceeds the standard. When the malfunction detection condition is met, the power management control ECU (HV CPU) illuminates the malfunction indicator light (MIL) and sets a diagnostic trouble code (DTC).

P0B86 – Hybrid/Electric Vehicle Battery 16 Circuit

P0B86 Possible Causes

  • Defective hybrid/electric vehicle battery
  • Faulty hybrid/electric vehicle battery interface control module

What Does It Mean?

How to Fix P0B86 Code

Check the “possible causes” listed above. Visually inspect the wiring harness and associated connectors. Check for damaged components and look for broken, bent, pushed out, or corroded connector pins.

P0B86 Possible Symptoms

Check engine light illuminated (or service engine soon warning light)

P0B86 Meaning

The hybrid/electric vehicle battery contains 288 cells. Groups of three cells are welded together in parallel. There are a total of 96 cell groups in the hybrid/EV battery pack. These cell groups are electrically connected in series. Each individual cell group is rated at 3.7 V, for a nominal system voltage of 355 V DC. The battery cells are also grouped into three sections. The first 90 cells/30 cell groups make up the first battery section. This section is adjacent to the hood and contains batteries 67 to 96. Battery section two is located behind section one. It consists of 72 cells/24 cell groups and contains batteries 43 to 66. The battery cross-section is section number three, it consists of the remaining 126 cells/42 cell groups and contains batteries 1 to 42. The three battery sections are individually repairable components.

The battery energy control module monitors the voltage of the 96 battery cell groups via the four hybrid/EV battery interface control modules. Voltage sensing circuits are attached to each individual cell group, and these sensing circuits terminate at a connector located on the top surface of the battery section. A serviceable auxiliary battery wiring harness connects this connector to a hybrid/EV battery interface control module, also located on the top surface of the battery section. The hybrid/EV battery interface control module encodes the voltage reading and transmits it to the battery energy control module via the battery control harness. There is one hybrid/EV battery interface control module located on battery sections one and two, and two hybrid/EV battery interface control modules associated with battery section three. The hybrid/EV battery interface control module, battery energy control module wiring harness, auxiliary battery wiring harness, and battery energy control module are all considered serviceable components.

The battery energy control module will determine when a fault condition is present. System diagnostics and status are communicated from the battery energy control module to the hybrid/EV powertrain control module 2 via serial data. The hybrid/EV powertrain control module 2 is the host controller for diagnostic trouble code information.

P0B87 – Performance of Hybrid/Electric Vehicle Battery Circuit 16

P0B87 Possible Causes

  • Defective hybrid/electric vehicle battery
  • Faulty hybrid/electric vehicle battery interface control module

What Does It Mean?

How to Fix P0B87 Code

Check the “possible causes” listed above. Visually inspect the wiring harness and related connectors. Check for damaged components and look for broken, bent, pushed out, or corroded connector pins.

P0B87 Possible Symptoms

Check engine light illuminated (or service engine soon warning light)

P0B87 Meaning

The hybrid/electric vehicle battery contains 288 cells. Groups of three cells are welded together in parallel. There are a total of 96 cell groups in the hybrid/EV battery pack. These cell groups are electrically connected in series. Each individual cell group is rated at 3.7 V, for a nominal system voltage of 355 V DC. The battery cells are also grouped into three sections. The first 90 cells/30 cell groups make up battery section one. This section is adjacent to the hood and contains batteries 67 to 96. Battery section two is located behind section one. It consists of 72 cells/24 cell groups and contains batteries 43 to 66. The battery cross-section is section number three, it consists of the remaining 126 cells/42 cell groups and contains batteries 1 to 42. The three battery sections are individually serviceable components.

The battery energy control module monitors the voltage of the 96 battery cell groups via the four hybrid/EV battery interface control modules. Voltage sensing circuits are attached to each individual cell group, and these sensing circuits terminate at a connector located on the top surface of the battery section. A serviceable auxiliary battery wiring harness connects this connector to a hybrid/EV battery interface control module, also located on the top surface of the battery section. The hybrid/EV battery interface control module encodes the voltage reading and transmits it to the battery energy control module via the battery control harness. There is one hybrid/EV battery interface control module located on battery sections one and two, and two hybrid/EV battery interface control modules associated with battery section three. The hybrid/EV battery interface control module, battery energy control module wiring harness, auxiliary battery wiring harness, and battery energy control module are all considered serviceable components.

The battery energy control module will determine when a fault condition is present. System diagnostics and status are communicated from the battery energy control module to the hybrid/EV powertrain control module 2 via serial data. The hybrid/EV powertrain control module 2 is the host controller for diagnostic trouble code information.

P0B88 – Low Voltage in Hybrid/Electric Vehicle Battery Circuit 16

P0B88 Possible Causes

  • Defective hybrid/electric vehicle battery
  • Faulty hybrid/electric vehicle battery interface control module

What Does It Mean?

How to Fix P0B88 Code

Check the “possible causes” listed above. Visually inspect the related wiring harness and connectors. Check for damaged components and look for broken, bent, pushed out, or corroded connector pins.

P0B88 Possible Symptoms

Check engine light illuminated (or service engine soon warning light)

P0B88 Meaning

The hybrid/electric vehicle battery contains 288 cells. Groups of three cells are welded together in parallel. There are a total of 96 cell groups in the hybrid/EV battery pack. These cell groups are electrically connected in series. Each individual cell group is rated at 3.7 V, for a nominal system voltage of 355 V DC. The battery cells are also grouped into three sections. The first 90 cells/30 cell groups make up battery section one. This section is adjacent to the hood and contains batteries 67 to 96. Battery section two is located behind section one. It consists of 72 cells/24 cell groups and contains batteries 43 to 66. The battery cross section is section number three, it consists of the remaining 126 cells/42 cell groups and contains batteries 1 to 42. The three battery sections are individually serviceable components.

The battery energy control module monitors the voltage of the 96 battery cell groups via the four hybrid/EV battery interface control modules. Voltage sensing circuits are attached to each individual cell group, and these sensing circuits terminate at a connector located on the top surface of the battery section. A serviceable auxiliary battery wiring harness connects this connector to a hybrid/EV battery interface control module, also located on the top surface of the battery section. The hybrid/EV battery interface control module encodes the voltage reading and transmits it to the battery energy control module via the battery control harness. There is one hybrid/EV battery interface control module located on battery sections one and two, and two hybrid/EV battery interface control modules associated with battery section three. The hybrid/EV battery interface control module, battery energy control module wiring harness, auxiliary battery wiring harness, and battery energy control module are all considered serviceable components.

The battery energy control module will determine when a fault condition is present. System diagnostics and status are communicated from the battery energy control module to the hybrid/EV powertrain control module 2 via serial data. The hybrid/EV powertrain control module 2 is the host controller for diagnostic trouble code information.