OBD2 Code P1422 Subaru: Complete Diagnosis of the EGR Valve Problem

Posted by

Understanding the P1422 Fault Code on Subaru Vehicles

What exactly does the OBD2 code P1422 mean?

The P1422 fault code is a manufacturer-specific code for Subaru that indicates a malfunction in the secondary EGR valve circuit. This system, also called the “secondary exhaust gas recirculation system,” plays a crucial role in reducing polluting emissions, particularly during the engine’s cold start phases. Unlike conventional EGR systems, the secondary system operates mainly during the first few minutes of engine operation to accelerate catalyst heating and improve exhaust gas treatment efficiency.

Operation of the secondary EGR system in Subaru

The Subaru secondary EGR system consists of several key components:

  • Secondary EGR valve (electric or pneumatic control)
  • Pressure and temperature sensors
  • Secondary air accumulation reservoir
  • Connection pipes to the exhaust manifold
  • Engine control unit (ECU) for system management

This system injects fresh air into the exhaust gas flow to promote afterburning that quickly raises the catalyst temperature, enabling more effective reduction of harmful emissions from startup.

Main Causes of P1422 Code Triggering

Electrical problems and component failures

The most frequent causes of the P1422 code on Subaru include:

  • Faulty secondary EGR valve: mechanical wear, blockage, or severe clogging
  • Electrical circuit problems: cut wires, oxidized connectors, or poor contacts
  • Control relay failure: inability to properly power the valve
  • Defective sensors: pressure sensor or temperature probe providing incorrect information to the ECU

Mechanical problems and clogging

Beyond electrical issues, several mechanical factors can trigger P1422:

  • Severe pipe clogging: accumulation of carbon deposits obstructing air passage
  • System leaks: cracks in pipes or poor sealing joints
  • Secondary air pump failure (on certain models): bearing wear or electric motor failure
  • Engine vacuum problems: leaks affecting the operation of pneumatic systems

Aggravating factors specific to Subaru models

Certain Subaru models have particular vulnerabilities:

  • Subaru Impreza (2002-2007 models): recurring problems with oxidized connectors
  • Subaru Forester (SG/SH generations): accelerated clogging in urban use
  • Subaru Legacy/Outback (4th generation): early control relay failures

Step-by-Step Diagnostic Procedure

Preparation and necessary tools

Before starting diagnosis, gather the appropriate tools:

  • Professional OBD2 scanner compatible with Subaru
  • Digital multimeter for electrical measurements
  • Vacuum pump (for pneumatic tests)
  • Specific cleaner for EGR circuits
  • Technical documentation for the concerned model

Electrical diagnosis of the secondary EGR valve circuit

Start by checking the electrical circuit integrity:

  • Check the valve supply voltage (generally 12V)
  • Verify the circuit ground with the multimeter
  • Test the valve coil resistance (specific values according to model)
  • Visually inspect the condition of connectors and wiring

Functional tests and mechanical checks

Once the electrical aspect is validated, proceed to mechanical tests:

  • Valve operation test with scanner (active command)
  • System leak check under vacuum
  • Visual inspection of secondary air pipes and conduits
  • Inspection of the accumulation reservoir for possible damage

Repair Solutions and Estimated Costs

System cleaning and decoking

For moderate clogging cases, thorough cleaning can solve the problem:

  • Disassembly and cleaning of the secondary EGR valve with specific products
  • Cleaning of air conduits with compressed air and suitable solvents
  • Check and clean the air filter (if present in the circuit)
  • Reassembly with replacement of sealing joints if necessary

Replacement of defective components

In case of proven failure, replacement is necessary:

  • New secondary EGR valve (original part recommended)
  • Control relay and wiring repair if damaged
  • Defective piping replaced with certified parts
  • Associated sensors if values are out of specifications

Repair cost estimation

The total cost varies according to the necessary intervention:

  • Complete system cleaning: €150-300 (labor included)
  • Secondary EGR valve replacement: €300-600 depending on model
  • Electrical circuit repair: €100-250
  • Complete system replacement: €500-900 for the most severe cases

Consequences and Prevention of P1422 Code

Risks if not repaired

Ignoring a P1422 code can lead to serious complications:

  • Significant increase in polluting emissions
  • Premature degradation of the catalyst (high replacement cost)
  • Increased fuel consumption
  • Risk of failure at technical inspection
  • Possibility of engine entering limp mode

Preventive measures to avoid fault recurrence

To minimize P1422 recurrence risks:

  • Use of quality fuel and occasional cleaning additives
  • Regular maintenance of the air intake system
  • Periodic checks of electrical connections
  • Replace air filter according to recommended intervals
  • Avoid exclusively very short urban trips

The Subaru P1422 code, although specific, generally responds well to structured diagnostic procedures. A methodical approach allowing precise identification of the root cause avoids unnecessary component replacements and ensures durable repair of your vehicle’s anti-pollution system.

Leave a Reply

Your email address will not be published. Required fields are marked *