P0A42 Drive Motor Position Sensor “A” Circuit

Posted by

P0A42 Possible Causes

  • Faulty inverter with converter assembly
  • Faulty hybrid vehicle generator assembly
  • Faulty hybrid vehicle motor assembly
  • Cable harness or connector

What Does It Mean?

How to Fix Code P0A42

Check the “possible causes” listed above. Visually inspect the cable harness and associated connectors. Check for damaged components and look for broken, bent, pushed out, or corroded connector pins.

P0A42 Possible Symptoms

Check engine light on (or service engine soon warning light)

P0A42 Meaning

A resolver is a sensor used to detect the position of magnetic poles in a motor-generator rotor. Knowledge of pole position is essential for precise control of MG2 and MG1.
Each resolver contains a stator with an excitation coil and 2 detection coils (S, C). The gap between stator and rotor changes as the rotor rotates because the rotor is oval-shaped. Alternating current with a predetermined frequency flows through the excitation coil, and the S and C detection coils produce alternating currents according to the sensor rotor position.
The inverter with converter (MG ECU) detects the absolute rotor position based on the phases of the S and C detection coils and their waveform amplitudes. Additionally, the CPU calculates the amount of position change over a predetermined time period to use the resolver as a speed sensor.
The MG ECU monitors signals from the motor resolver and detects malfunctions.