P240B – Evaporative Emission System Leak Detection Pump Heater Control Circuit

Posted by

P240B Possible Causes

  • Faulty leak detection pump
  • Leak detection pump circuit open or shorted
  • Poor electrical connection in leak detection pump circuit

How to Fix Code P240B

Check the “Possible Causes” listed above. Visually inspect the related wiring harness and connectors. Check for damaged components and look for broken, bent, pushed out, or corroded connector pins.

P240B Possible Symptoms

Illuminated check engine light (or service engine soon warning light)

P240B Meaning

The engine control module (ECM) monitors the power consumption of the leak detection pump. This diagnostic trouble code (DTC) can be diagnosed when the leak diagnostic system is running. A DTC is stored if the actual current consumption of the pump in the leak detection pump unit varies too much during the reference phase.