P100B – VVEL 2 Response Malfunction Bank

Posted by

P100B Code Description

  • The VVEL (Variable Valve Event & Lift) system controls the lift and opening of the intake valves.
  • It uses a drive shaft, eccentric cams, rocker arms, and linkages to modify valve lift.
  • The Engine Control Module (ECM) adjusts the valve lift based on driving conditions.
  • The VVEL control module controls the rotation of the control shaft using the VVEL actuator motor.
  • The goal is to optimize engine power and response.

Possible Symptoms

  • Check Engine light illuminated.

Possible Causes

  • Faulty VVEL actuator motor.
  • VVEL actuator motor wiring harness open or shorted.
  • Poor electrical connection in the VVEL actuator motor circuit.
  • Faulty VVEL actuator assembly.
  • Faulty VVEL ladder assembly.
  • Faulty VVEL control module.

Repair Procedure

  1. Visual Inspection:
    • Check the cables and connectors associated with the VVEL actuator motor.
    • Look for signs of damage: frayed wires, corroded connectors, bent or broken pins.
  2. Component Verification:
    • If the visual inspection reveals no issues, test the VVEL actuator motor.
    • Check the VVEL actuator assembly.
    • Check the VVEL ladder assembly.
    • Check the VVEL control module.
    • If possible, test wire continuity.

Leave a Reply